一、產品簡介
1.1概述
DTSD/DSSD6111型(xing)電子(zi)式三相(xiang)智(zhi)能電能表是采用集成電路,應用數(shu)字采樣處(chu)理(li)技術(shu)及SMT工藝,根(gen)據工業(ye)用戶實(shi)際用電狀況所設計、制(zhi)造(zao)的儀表。
該表性(xing)能(neng)(neng)(neng)(neng)(neng)指(zhi)標(biao)符(fu)合GB/T 17215.323-2008《交流電(dian)(dian)測量(liang)設(she)備 特(te)(te)殊(shu)(shu)要求 第23部分:靜止式無功(gong)(gong)電(dian)(dian)能(neng)(neng)(neng)(neng)(neng)表(2級(ji)(ji)和3級(ji)(ji))》、GB/T 17215.321-2008《交流電(dian)(dian)測量(liang)設(she)備 特(te)(te)殊(shu)(shu)要求 第21部分:靜止式有(you)功(gong)(gong)電(dian)(dian)能(neng)(neng)(neng)(neng)(neng)表(1級(ji)(ji)和2級(ji)(ji))》、GB/T 17215.301-2007《多(duo)(duo)功(gong)(gong)能(neng)(neng)(neng)(neng)(neng)電(dian)(dian)能(neng)(neng)(neng)(neng)(neng)表 特(te)(te)殊(shu)(shu)要求》、DL/T 614-2007《多(duo)(duo)功(gong)(gong)能(neng)(neng)(neng)(neng)(neng)電(dian)(dian)能(neng)(neng)(neng)(neng)(neng)表》、Q/GDW 362-2009《1級(ji)(ji)三相(xiang)費控智(zhi)能(neng)(neng)(neng)(neng)(neng)電(dian)(dian)能(neng)(neng)(neng)(neng)(neng)表技(ji)術(shu)規(gui)(gui)范》和Q/GDW 363-2009《1級(ji)(ji)三相(xiang)智(zhi)能(neng)(neng)(neng)(neng)(neng)電(dian)(dian)能(neng)(neng)(neng)(neng)(neng)表技(ji)術(shu)規(gui)(gui)范》標(biao)準對(dui)多(duo)(duo)功(gong)(gong)能(neng)(neng)(neng)(neng)(neng)電(dian)(dian)能(neng)(neng)(neng)(neng)(neng)表的(de)各項技(ji)術(shu)要求,其通信符(fu)合DL/T 645-2007《多(duo)(duo)功(gong)(gong)能(neng)(neng)(neng)(neng)(neng)表通信規(gui)(gui)約》的(de)要求。
該(gai)表(biao)能(neng)(neng)計量各(ge)個方向的有(you)(you)功(gong)、無(wu)功(gong)電量及(ji)需(xu)量, 分相(xiang)計量有(you)(you)功(gong)、無(wu)功(gong)電能(neng)(neng),具有(you)(you)雙路RS485和調制式紅外通訊(xun)、按鍵及(ji)紅外停電喚醒抄表(biao)等功(gong)能(neng)(neng),它性能(neng)(neng)穩(wen)定(ding)、準確度高、操作方便。
1.2 工(gong)作原理
三相智能電能表是由測量(liang)單(dan)元和(he)(he)數據處理單(dan)元等組成,除計量(liang)有功(gong)(無功(gong))電能量(liang)外(wai),還具(ju)有分時、測量(liang)需量(liang)等兩(liang)種以上功(gong)能,并能顯示、儲存和(he)(he)輸(shu)出數據的(de)電能表。
DTSD6111型(xing)電(dian)子式(shi)三相(xiang)智能電(dian)能表(biao)工作原(yuan)理如圖1所(suo)示:
圖1 三相智(zhi)能電能表工作原理框圖
電(dian)(dian)能(neng)表(biao)工(gong)(gong)作時(shi),電(dian)(dian)壓(ya)、電(dian)(dian)流經(jing)取(qu)樣(yang)電(dian)(dian)路(lu)分(fen)別取(qu)樣(yang)后(hou),送至放大電(dian)(dian)路(lu)緩沖放大,再由計(ji)(ji)量(liang)芯片(pian)轉換(huan)為數(shu)字信號,高性能(neng)微控制器負(fu)責對數(shu)據(ju)進行分(fen)析處(chu)理。由于(yu)采(cai)(cai)用精度高的計(ji)(ji)量(liang)芯片(pian),計(ji)(ji)量(liang)芯片(pian)自行完(wan)成前端高速(su)采(cai)(cai)樣(yang),計(ji)(ji)量(liang)算法(fa)穩定,微控制器僅(jin)需要管理和(he)控制計(ji)(ji)量(liang)芯片(pian)的工(gong)(gong)作狀態。圖中的微控制器還(huan)用于(yu)分(fen)時(shi)計(ji)(ji)費和(he)處(chu)理各種輸(shu)入(ru)輸(shu)出數(shu)據(ju),并(bing)根(gen)據(ju)預先設定的時(shi)段完(wan)成分(fen)時(shi)有、無功(gong)電(dian)(dian)能(neng)計(ji)(ji)量(liang)和(he)最大需量(liang)計(ji)(ji)量(liang)功(gong)能(neng),根(gen)據(ju)需要顯示各項(xiang)數(shu)據(ju)、通過(guo)紅外或485接口進行通訊傳輸(shu),并(bing)完(wan)成運行參數(shu)的監測,記錄(lu)存(cun)儲(chu)各種數(shu)據(ju)。
1.3技術(shu)指標(biao)
準確度等(deng)級 有(you)功0.2S級、0.5S級、1級 無(wu)功2級
額定頻率(lv) 50Hz
起動電流 有(you)功(gong) 0.001In(0.2S級、0.5S級); 0.002In(直(zhi)入式0.004In )(1.0級)
無功(gong) 0.003In(直入(ru)式0.005In )(2.0級)
潛動(dong) 具有防潛(qian)動邏輯(ji)設計(ji)
外(wai)型(xing)尺寸(cun) 265mm′170mm′75mm
重量 約2.5kg
電(dian)氣(qi)參數
正常工作電(dian)壓 |
0.8Un~1.2Un |
極限工(gong)作(zuo)電壓 |
0.7Un~1.3Un |
電壓線路(lu)功耗 |
≤1.5W和5 VA (輔助電(dian)源≤10VA) |
電流(liu)線路功耗 |
<2 VA |
時(shi)鐘電(dian)池電(dian)壓 |
3.6V |
停(ting)電抄表電池電壓 |
3.0V |
復費(fei)率工作參數(shu)
時鐘準(zhun)確度(日誤差) |
≤0.5s/d(溫(wen)度(du)-30℃~+65℃) |
時鐘電(dian)池容量 |
≥1200mAh |
停電后數據保存時(shi)間 |
≥10年 |
氣(qi)候條件
正常工(gong)作溫度 |
-20℃~+60℃ |
極限工作溫度(du) |
-30℃~+70℃ |
存(cun)貯和運輸溫度 |
-40℃~+70℃ |
存儲和(he)工作濕度 |
≤85%RH |
二、外(wai)形說明及(ji)安裝
2.1
2.2電(dian)表(biao)的安(an)裝及接線
1) 電(dian)(dian)能(neng)表(biao)(biao)(biao)安(an)裝在室內通風干燥(zao)的(de)(de)地方,確保(bao)安(an)裝使用安(an)全、可靠,在有污(wu)穢或可能(neng)損壞電(dian)(dian)能(neng)表(biao)(biao)(biao)的(de)(de)場所(suo),電(dian)(dian)能(neng)表(biao)(biao)(biao)應用保(bao)護(hu)柜保(bao)護(hu)。
2)安(an)裝尺(chi)寸
電能表上部(bu)有掛鉤(gou)螺釘孔(kong),下部(bu)有2個安(an)裝孔(kong),用M4×15螺釘固定。按下圖所示的安(an)裝尺寸(cun),固定在堅固、耐火、不易震動的物(wu)體上。
三相智能(neng)電能(neng)表安裝(zhuang)圖(tu)
4)端子接(jie)線圖
1、功能(neng)端子接線圖
2、電源端子(zi)接線圖
三、基本功能
3.1 電能(neng)(neng)計量功能(neng)(neng)
1)電能計(ji)量記錄內容
名 稱 |
數據標識 |
具體內容 |
有功組合電能 *注1 |
0000xxxx |
當前、上1結算日~上12結算日*注(zhu)3總(zong)、各費率電能 |
正向有(you)功電能 |
0001xxxx |
當前、上1結算日(ri)~上12結算日(ri)總(zong)、各費率電能 |
反向(xiang)有(you)功(gong)電能(neng) |
0002xxxx |
當(dang)前(qian)、上1結算(suan)(suan)日~上12結算(suan)(suan)日總、各(ge)費率電能 |
組合無功1電(dian)能(neng) *注2 |
0003xxxx |
當前、上(shang)1結算(suan)日~上(shang)12結算(suan)日總、各費率(lv)電能 |
組(zu)合(he)無(wu)功2電能 *注(zhu)2 |
0004xxxx |
當前、上(shang)1結(jie)(jie)算日(ri)~上(shang)12結(jie)(jie)算日(ri)總、各費率電能 |
第一象(xiang)限(xian)無功電能 |
0005xxxx |
當前(qian)、上(shang)1結算(suan)日~上(shang)12結算(suan)日總(zong)、各費率電能 |
第二象(xiang)限無功電能 |
0006xxxx |
當前、上1結算日~上12結算日總、各費率電能 |
第三象限無功電能(neng) |
0007xxxx |
當前、上1結算日~上12結算日總、各費率電能(neng) |
第四象限(xian)無功電能 |
0008xxxx |
當前、上(shang)(shang)1結算日~上(shang)(shang)12結算日總、各費率電能 |
分相正向有功電(dian)能 |
00xx00xx |
當前、上(shang)1結(jie)(jie)算日(ri)~上(shang)12結(jie)(jie)算日(ri)總電能(neng) |
分(fen)相反向(xiang)有功電能(neng) |
當(dang)前(qian)、上1結算日~上12結算日總(zong)電能 |
|
分相組合無功1電能(neng) |
當前、上(shang)1結算(suan)日~上(shang)12結算(suan)日總(zong)電能 |
|
分相組合無功2電(dian)能 |
當(dang)前、上1結(jie)算日~上12結(jie)算日總電能(neng) |
注(zhu)1:正向有(you)(you)功(gong)(gong)電能的計量方(fang)法取決于 “有(you)(you)功(gong)(gong)組合方(fang)式特征字(zi)”的內容。
注(zhu)2:正、反向無(wu)功電能(neng)的計量(liang)方法取(qu)決于 “無(wu)功組(zu)合方式1、2特征字”的內(nei)容。
注3:三(san)個結(jie)算日(ri)(ri)只能設置(zhi)為合法時(shi)(shi)間或99日(ri)(ri)99分,設置(zhi)為99日(ri)(ri)99分時(shi)(shi)表計不結(jie)算。
有功組合方(fang)式特征字
Bit7 |
Bit6 |
Bit5 |
Bit4 |
Bit3 |
Bit2 |
Bit1 |
Bit0 |
保(bao)留 |
保留 |
保留 |
保留(liu) |
反向有功(gong) (0不減,1減) |
反向(xiang)有功 (0不加,1加) |
正向(xiang)有功 (0不減,1減) |
正(zheng)向有功 (0不加,1加) |
無功組合方式1、2特(te)征字
Bit7 |
Bit6 |
Bit5 |
Bit4 |
Bit3 |
Bit2 |
Bit1 |
Bit0 |
IV象限 (0不減,1減) |
IV象限 (0不加,1加) |
III象限 (0不減,1減) |
III象限 (0不加,1加) |
II象限(xian) (0不(bu)減,1減) |
II象限 (0不加,1加) |
I象限 (0不減,1減) |
I象(xiang)限 (0不加(jia),1加(jia)) |
3.2 最大(da)需量(liang)記(ji)錄功能(neng)
最大需(xu)量:在指(zhi)定的時間區間內,需量周期中測得的平均功率最大值。
需量周期:測(ce)量(liang)平均(jun)功率的連續相等的時間間隔。最大需量(liang)周期(qi)可5/10/15/30/60分鐘任(ren)選一種。
滑(hua)差時間(jian):依次遞(di)推來測(ce)量(liang)最大需(xu)量(liang)的小于需(xu)量(liang)周期的時間(jian),滑差(cha)時間(jian)可以在1/2/3/5min選擇。
最大需量及發(fa)生時(shi)間記(ji)錄內容(rong)
名 稱 |
數據標(biao)識 |
具體內容 |
正向有(you)功(gong)最大需量及其發生時間 |
0101xxxx |
當前(qian)、上1結(jie)算日~上(shang)12結算日總、各費(fei)率最大(da)需量(liang)及其(qi)發生時間 |
反向有功(gong)最(zui)大(da)需量及其發生時間(jian) |
0102xxxx |
當前、上1結算日(ri)~上12結(jie)算(suan)日總(zong)、各費率最大需量(liang)及其發生時(shi)間 |
組合無功1最大(da)需(xu)量及(ji)其發(fa)生時間 |
010300xx |
當前、上(shang)1結(jie)算日~上12結算(suan)日(ri)總最(zui)大需(xu)量(liang)及其(qi)發(fa)生時(shi)間 |
組合無(wu)功2最(zui)大需量及其發生時間 |
010400xx |
當前、上1結算日~上12結(jie)算日總(zong)最大(da)需量及其(qi)發生時(shi)間 |
四象限無功最大(da)需量(liang)及(ji)其發生(sheng)時(shi)間(jian) |
01xx00xx |
當(dang)前、上1結算日~上12結(jie)算日總(zong)最大需量及其(qi)發生時間 |
注:最大需量記錄數據(ju)不(bu)帶(dai)符號(hao),以瞬時功率(lv)方向為準(zhun)。最大需量按每月第1結算(suan)(suan)日(ri)結算(suan)(suan),第2、第3結算(suan)(suan)日(ri)不(bu)結算(suan)(suan),相應數據(ju)填(tian)0xFF。
3.3 復(fu)費(fei)率功能
年時區數:電能(neng)表(biao)能(neng)運(yun)(yun)行(xing)(xing)的時(shi)(shi)(shi)區(qu)。如果年(nian)時(shi)(shi)(shi)區(qu)數(shu)小(xiao)于已(yi)編程(cheng)的年(nian)時(shi)(shi)(shi)區(qu),則(ze)電能(neng)表(biao)只運(yun)(yun)行(xing)(xing)前面幾(ji)個時(shi)(shi)(shi)區(qu)(如年(nian)時(shi)(shi)(shi)區(qu)數(shu)為2,則(ze)運(yun)(yun)行(xing)(xing)前2個時(shi)(shi)(shi)區(qu))。年(nian)時(shi)(shi)(shi)區(qu)數(shu)編為0,則(ze)電能(neng)表(biao)只運(yun)(yun)行(xing)(xing)第一個時(shi)(shi)(shi)區(qu)(不管編程(cheng)時(shi)(shi)(shi)編設了幾(ji)個時(shi)(shi)(shi)區(qu))。年(nian)時(shi)(shi)(shi)區(qu)數(shu)不超(chao)過14。
日時段表數:電(dian)(dian)能表(biao)能運行的(de)(de)日(ri)時(shi)(shi)(shi)段(duan)(duan)表(biao)號(hao)。如果日(ri)時(shi)(shi)(shi)段(duan)(duan)表(biao)數(shu)設為(wei)4,則電(dian)(dian)表(biao)的(de)(de)第(di)5到(dao)第(di)8日(ri)時(shi)(shi)(shi)段(duan)(duan)表(biao)無效,即使(shi)某個(ge)時(shi)(shi)(shi)區的(de)(de)日(ri)時(shi)(shi)(shi)段(duan)(duan)表(biao)號(hao)被設為(wei)5,該時(shi)(shi)(shi)區會按(an)第(di)4日(ri)時(shi)(shi)(shi)段(duan)(duan)表(biao)的(de)(de)時(shi)(shi)(shi)段(duan)(duan)運行,而不(bu)(bu)會按(an)第(di)5日(ri)時(shi)(shi)(shi)段(duan)(duan)表(biao)的(de)(de)時(shi)(shi)(shi)段(duan)(duan)運行。如日(ri)時(shi)(shi)(shi)段(duan)(duan)表(biao)數(shu)編為(wei)0,則電(dian)(dian)表(biao)只運行第(di)1日(ri)時(shi)(shi)(shi)段(duan)(duan)表(biao)。日(ri)時(shi)(shi)(shi)段(duan)(duan)表(biao)數(shu)不(bu)(bu)超過8。
日時(shi)段數:電(dian)(dian)能表(biao)每(mei)天能運行的(de)日(ri)時(shi)(shi)段。不(bu)超過14。如果日(ri)時(shi)(shi)段數(shu)設為(wei)4,則每(mei)個日(ri)時(shi)(shi)段表(biao)的(de)第(di)5~14時(shi)(shi)段的(de)時(shi)(shi)間電(dian)(dian)表(biao)將(jiang)視作(zuo)無效(xiao),只有(you)前4個時(shi)(shi)段的(de)時(shi)(shi)間有(you)效(xiao)。如設為(wei)0,則電(dian)(dian)表(biao)只運行第(di)一個日(ri)時(shi)(shi)段。
日(ri)時段表號:編程時(shi)用(yong)來表(biao)(biao)(biao)(biao)示(shi)(shi)電(dian)表(biao)(biao)(biao)(biao)運行在第幾日時(shi)段表(biao)(biao)(biao)(biao),用(yong)1、2、3、4、5、6、7、8表(biao)(biao)(biao)(biao)示(shi)(shi)。如時(shi)區的日時(shi)段表(biao)(biao)(biao)(biao)號被設為0,則電(dian)表(biao)(biao)(biao)(biao)固定為第1日時(shi)段表(biao)(biao)(biao)(biao)。
費(fei)率(lv)數:電能(neng)表(biao)能(neng)切換的費率號數。其值不超(chao)過4。若設為3,則只有費率1、費率2、費率3有效,依此類推。如為0,則電表(biao)不論在(zai)哪個日時段(duan),只運行費率1。
費率號:編程時用來表(biao)示電表(biao)運行在(zai)何種費率(lv)(lv),用1、2、3、4、表(biao)示。通常分別對應尖費率(lv)(lv)、峰費率(lv)(lv)、平費率(lv)(lv)、谷費率(lv)(lv)。
公共假日數:電能表(biao)一(yi)年中能運行在公共(gong)假日狀(zhuang)態下的(de)天數(shu)。如為0,表(biao)示(shi)公共(gong)假日選(xuan)擇無效。其值不超過10。
公共假日:一般指國家(jia)規定的假日,如1月1日、5月1日(ri)、春節等,用戶可設置。
公共(gong)假日日期及日時段表號:設定(ding)一年(nian)中的(de)公共假日(ri)(ri)日(ri)(ri)期及采(cai)用(yong)的(de)日(ri)(ri)時段表號(hao)(hao),不同(tong)的(de)公共假日(ri)(ri)可采(cai)用(yong)不同(tong)的(de)日(ri)(ri)時段表號(hao)(hao)。
周休日:一(yi)般指一(yi)周內規(gui)定的(de)休(xiu)(xiu)息日(ri)。由周休(xiu)(xiu)日(ri)特(te)征字(zi)來設定每周的(de)工作日(ri)和休(xiu)(xiu)息日(ri)。
周(zhou)休日采用的日時(shi)段(duan)表號(hao):按需要設定(ding)休息日(ri)采用的日(ri)時(shi)段表(biao)號。
多(duo)時區編程說(shuo)明:本電(dian)表可編設14個時區。
注:以上參數(shu)均可通(tong)過掌上電腦或PC機進行設置,詳見附錄B。
下面舉例說明:
例:某個地(di)區(qu)(qu)將一(yi)年分成兩個時(shi)(shi)(shi)(shi)區(qu)(qu),第一(yi)時(shi)(shi)(shi)(shi)區(qu)(qu)從1月(yue)1日(ri)(ri)開始(shi),采用第1日(ri)(ri)時(shi)(shi)(shi)(shi)段(duan)(duan)表(biao),第二時(shi)(shi)(shi)(shi)區(qu)(qu)從9月(yue)1日(ri)(ri)開始(shi),采用第2日(ri)(ri)時(shi)(shi)(shi)(shi)段(duan)(duan)表(biao)。第1日(ri)(ri)時(shi)(shi)(shi)(shi)段(duan)(duan)為(wei)(wei):第1時(shi)(shi)(shi)(shi)段(duan)(duan)起始(shi)時(shi)(shi)(shi)(shi)間(jian)(jian)7:00費(fei)率(lv)(lv)2,第2時(shi)(shi)(shi)(shi)段(duan)(duan)起始(shi)時(shi)(shi)(shi)(shi)間(jian)(jian)21:00費(fei)率(lv)(lv)3;第2日(ri)(ri)時(shi)(shi)(shi)(shi)段(duan)(duan)為(wei)(wei):第1時(shi)(shi)(shi)(shi)段(duan)(duan)起始(shi)時(shi)(shi)(shi)(shi)間(jian)(jian)8:00費(fei)率(lv)(lv)2,第2時(shi)(shi)(shi)(shi)段(duan)(duan)起始(shi)時(shi)(shi)(shi)(shi)間(jian)(jian)22:00費(fei)率(lv)(lv)3。假設5月(yue)1日(ri)(ri)和(he)10月(yue)1日(ri)(ri)為(wei)(wei)公共假日(ri)(ri)。公共假日(ri)(ri)的時(shi)(shi)(shi)(shi)段(duan)(duan)為(wei)(wei):第1時(shi)(shi)(shi)(shi)段(duan)(duan)起始(shi)時(shi)(shi)(shi)(shi)間(jian)(jian)9:00費(fei)率(lv)(lv)1,第2時(shi)(shi)(shi)(shi)段(duan)(duan)起始(shi)時(shi)(shi)(shi)(shi)間(jian)(jian)21:00費(fei)率(lv)(lv)2,第3時(shi)(shi)(shi)(shi)段(duan)(duan)起始(shi)時(shi)(shi)(shi)(shi)間(jian)(jian)5:00費(fei)率(lv)(lv)3。具(ju)體設置應如下:
名 稱 |
數據標識 |
設置數據 |
備 注 |
年時區數 |
04000201 |
02 |
設置2個年時區 |
日時段表數 |
04000202 |
08 |
目前有8個日時段分配表,如果用戶想把公共假日對應的日時段表號設(she)為5的話,則該項必須(xu)設(she)為5,讓第5日時段表有效。 |
日時段數 |
04000203 |
02 |
一(yi)天可切換時段為(wei)2 |
費率數 |
04000204 |
04 |
因目前用(yong)了平費(fei)率,該(gai)項(xiang)數(shu)據必須≥3。 |
公共(gong)假日數 |
04000205 |
10 |
因(yin)目(mu)前有(you)兩個假(jia)日,該項數據(ju)必須≥2,當(dang)不大(da)于2時,電表將判斷第(di)2公(gong)(gong)共(gong)假(jia)日以下(xia)的公(gong)(gong)共(gong)假(jia)日為0,則該公(gong)(gong)共(gong)假(jia)日無效。 |
第1時(shi)區(qu)起(qi)始日期及(ji)日時(shi)段表號 |
04010000 |
010101 |
代表第1時區(qu)的起(qi)始日期為1月1日,該時區(qu)啟動日時段表1。 |
第2時(shi)(shi)區起始日期(qi)及日時(shi)(shi)段表(biao)號 |
04010000 |
090102 |
代表第2時(shi)(shi)區的起始日期為9月1日,該時(shi)(shi)區啟動日時(shi)(shi)段表2。 |
第1日時段表第1時段起始時間及費率號(hao) |
04010001 |
070002 |
代(dai)表(biao)第1日時(shi)(shi)段表(biao)第1時(shi)(shi)段的(de)起始時(shi)(shi)間為7:00,該時(shi)(shi)段啟用(yong)峰費率。 |
第(di)1日時(shi)段表第(di)2時(shi)段起(qi)始時(shi)間及費率號(hao) |
04010001 |
210003 |
代表(biao)第(di)1日時段表(biao)第(di)2時段的(de)起(qi)始時間為(wei)21:00,該時段啟(qi)用平費率。 |
第(di)(di)1日(ri)時段表(biao)第(di)(di)3時段起始(shi)時間及費率號 |
04010001 |
210003 |
第3時段(duan)及以(yi)(yi)下時段(duan)都得設為(wei)與第2時段(duan)一樣,這樣電表才認為(wei)第3時段(duan)及以(yi)(yi)下時段(duan)為(wei)無(wu)效。 |
第(di)2日時段表第(di)1時段起始(shi)時間及費率(lv)號(hao) |
04010002 |
080002 |
代表(biao)第(di)2日(ri)時(shi)(shi)段表(biao)第(di)1時(shi)(shi)段的起始時(shi)(shi)間為8:00,該時(shi)(shi)段啟用峰費率。 |
第2日時段表第2時段起始時間(jian)及費率號 |
04010002 |
220003 |
代表第(di)2日時段表第(di)2時段的起始時間為22:00,該時段啟用平費率(lv)。 |
第2日時(shi)段(duan)表第3時(shi)段(duan)起始(shi)時(shi)間及費率(lv)號(hao) |
04010002 |
220003 |
第3時段及(ji)(ji)以下時段都得(de)設為(wei)與第2時段一(yi)樣(yang),這樣(yang)電表(biao)才認為(wei)第3時段及(ji)(ji)以下時段為(wei)無效。 |
第1公(gong)共假日日期及(ji)日時段(duan)表號(hao) |
04030001 |
08050103 |
代表第一(yi)公共假日(ri)(ri)的日(ri)(ri)期為08年(nian)5月1日(ri)(ri),啟動日(ri)(ri)時(shi)段表3。 |
第2公共(gong)假日日期及(ji)日時段(duan)表號 |
04030002 |
08100103 |
代(dai)表第一公共假日(ri)的日(ri)期為08年10月1日(ri),啟動日(ri)時段表3。 |
第3日時段表第1時段起始時間及費率號 |
04010003 |
090001 |
代表第3日時段表第1時段的起始時間為9:00,該(gai)時段啟用尖(jian)費率。 |
第3日時(shi)段(duan)表第2時(shi)段(duan)起始時(shi)間及費率號 |
04010003 |
210002 |
代表第3日時段(duan)表第2時段(duan)的起始時間為(wei)21:00,該時段(duan)啟用峰(feng)費率。 |
第(di)3日(ri)時(shi)段(duan)表第(di)3時(shi)段(duan)起始時(shi)間及費率(lv)號 |
04010003 |
050003 |
代表第3日時段表第3時段的(de)起始時間為5:00,該(gai)時段啟用平費率。 |
第3日時段表第4時段起(qi)始時間及費率號 |
04010003 |
050003 |
第(di)4時(shi)(shi)段(duan)及(ji)以下時(shi)(shi)段(duan)都得設(she)為與第(di)3時(shi)(shi)段(duan)一樣,這樣電表才認為第(di)4時(shi)(shi)段(duan)及(ji)以下時(shi)(shi)段(duan)為無效(xiao)。 |
周(zhou)休日(ri)采用的日(ri)時段表號(hao) |
04000801 |
00 |
目前未啟(qi)用周(zhou)休(xiu)(xiu)日,若需啟(qi)用,必須先設置好周(zhou)休(xiu)(xiu)日特征字(zi),選(xuan)擇第1~8日時段(duan)(duan)表(biao)中的(de)(de)一個,只要星(xing)(xing)期一到星(xing)(xing)期日中的(de)(de)某一天(tian)被(bei)選(xuan)為休(xiu)(xiu)息日,則將按該項數據設置的(de)(de)日時段(duan)(duan)表(biao)運行。 |
電(dian)表具有(you)2套時區(qu)表和2套日時(shi)段表功能
電表(biao)(biao)具備2套時(shi)(shi)(shi)區(qu)(qu)表(biao)(biao)和2套日(ri)時(shi)(shi)(shi)段表(biao)(biao),還有與之對應的2套時(shi)(shi)(shi)區(qu)(qu)表(biao)(biao)切換時(shi)(shi)(shi)間(jian)和2套日(ri)時(shi)(shi)(shi)段表(biao)(biao)切換時(shi)(shi)(shi)間(jian)。通過提(ti)前設(she)置切換時(shi)(shi)(shi)間(jian)可(ke)(ke)以(yi)實現在用(yong)表(biao)(biao)統一(yi)時(shi)(shi)(shi)間(jian)轉(zhuan)換時(shi)(shi)(shi)段表(biao)(biao)或時(shi)(shi)(shi)區(qu)(qu)表(biao)(biao),避免因切換時(shi)(shi)(shi)間(jian)不一(yi)致造成的客戶糾紛。例如當(dang)用(yong)戶時(shi)(shi)(shi)區(qu)(qu)不變(bian)需要調整費率時(shi)(shi)(shi)段時(shi)(shi)(shi)可(ke)(ke)以(yi)先(xian)抄(chao)讀(du)電表(biao)(biao)運(yun)行(xing)狀態(tai)3,從 bit0了解電表(biao)(biao)當(dang)前使用(yong)的是第幾套日(ri)時(shi)(shi)(shi)段表(biao)(biao),然后(hou)對未(wei)使用(yong)的日(ri)時(shi)(shi)(shi)段表(biao)(biao)進(jin)行(xing)編程,再設(she)置好日(ri)時(shi)(shi)(shi)段表(biao)(biao)切換時(shi)(shi)(shi)間(jian),這樣(yang)便完成了整個修改(gai)操(cao)作,電表(biao)(biao)時(shi)(shi)(shi)鐘到達切換時(shi)(shi)(shi)間(jian)即可(ke)(ke)自動將2套日(ri)時(shi)(shi)(shi)段表(biao)(biao)進(jin)行(xing)調換。
2套(tao)時(shi)區(qu)(qu)表(biao)和2套(tao)日(ri)時(shi)段表(biao)切(qie)(qie)換(huan)(huan)日(ri)期:當(dang)電表(biao)當(dang)前時(shi)間(jian)在該日(ri)期之后(hou)(hou)時(shi),電表(biao)將自動(dong)切(qie)(qie)換(huan)(huan)使用另(ling)一(yi)套(tao)時(shi)段,切(qie)(qie)換(huan)(huan)后(hou)(hou)該切(qie)(qie)換(huan)(huan)日(ri)期自動(dong)恢(hui)復(fu)為(wei)00.00.00.00·00。當(dang)該切(qie)(qie)換(huan)(huan)日(ri)期設置為(wei)99.99.99.99·99時(shi),將切(qie)(qie)換(huan)(huan)到第(di)1套(tao)時(shi)區(qu)(qu)表(biao)和第(di)1套(tao)日(ri)時(shi)段表(biao)。
第2套時區表和日時段表設置項(xiang):其設置方(fang)法同以上(shang)時(shi)段表設置內容(rong)。
注:在設置另一(yi)套(tao)(tao)時(shi)段時(shi)最(zui)好先設置好另一(yi)套(tao)(tao)時(shi)段表(biao)的內(nei)容,再(zai)查詢電表(biao)當前時(shi)間(jian)是否(fou)正確(若不正確請校時(shi)),最(zui)后再(zai)設置2套(tao)(tao)時(shi)區表(biao)和(he)日時(shi)段表(biao)切換日期(qi)(保證該日期(qi)在當前日期(qi)之(zhi)后,否(fou)則電表(biao)將會立即切換)。